Products > Crane Ropes > High Performance

High Performance

Jump to :-
Verotop | Notor HP | NRHD 24 | AGM NUFLEX

Verotop

Nominal Diameter Calculated Breaking Strength Minimum Breaking Strength Approx. Weight
1960 Grade 2160 Grade 1960 Grade 2160 Grade
mm inch kN t(M) kN t(M) kN t(M) kN t(M) kg/m
10 113.111.54124.112.6691.42 9.8197.55 9.950.510
12 162.916.61178.718.22131.613.42140.514.320.735
12.7 1/2182.518.61200.220.41147.515.04157.316.040.823
13 191.219.50209.821.39154.515.75164.916.810.862
14 221.822.61243.324.80149.218.27191.219.501.000
15 254.625.96279.328.47205.720.97219.522.381.148
16 5/8289.629.53317.732.40234.023.86249.725.461.306
17 327.033.34358.736.57264.226.94281.928.751.475
18 366.637.38402.141.00296.230.20316.132.231.653
19 3/4408.541.65448.045.69330.033.65352.235.911.842
20 452.646.15496.450.62365.737.29390.239.792.041
21 499.050.88547.355.81403.241.11430.243.872.250
22 547.655.84600.761.25442.545.12472.248.142.470
22.4 7.8567.757.89622.763.50458.746.77489.549.912.561
23 598.561.03656.666.95483.649.31516.152.622.700
24 651.766.45714.972.90526.653.69561.957.302.939
25 707.272.11775.779.10571.458.26609.762.173.189
25.4 1730.074.43800.781.65589.860.14629.464.183.292
26 764.977.99839.085.55618.063.02659.567.243.450
27 824.884.11904.892.26666.567.96711.272.523.720
28 887.190.45973.099.22716.773.08764.877.994.001
28.61-1/8925.594.371.015103.5747.876.25797.981.364.174
29 951.597.031.044106.4768.878.40820.483.664.292
30 1018103.81.117113.9822.883.90878.089.524.593
31 1087110.91.193121.6878.689.58937.595.594.904
321-1/4 1159118.11.271129.6936.195.46998.9101.95.226
33 1232125.61.352137.8995.6101.5 1062108.35.557
34 1308133.41.435146.3 1057107.8 1128115.05.899
351-3/8 1386141.31.520155.0 1120114.2 1195121.96.251
36 1466149.51.608164.0 1185120.8 1264128.96.617
38 1634166.61.792182.7 1320134.6 1409143.67.369
40 1810184.61.986202.5 1463149.2 1561159.28.165

Notor HP

  • Exceptional non-rotating characteristics
  • Very high breaking load
  • Excellent service life
  • High resistance to corrosion
  • Highly flexible
  • Equal layed core to prevent cross nicking
  • Die-shaped strands
  • Ordinary lay finish
  • Galvanised steel 2160 MPa
  • Specific lubrication

28 x 7
(f=0.690 & k=0.830)
Rope diameter (mm) Outer Wire Diameter (mm) Mass (Kg/m) Minimum Breaking Load (kN)
10.00 0.53 0.465 96.00
12.00 0.64 0.685 147.00
13.00 0.70 0.800 162.20
14.00 0.75 0.925 188.00
15.00 0.80 1.060 218.00
16.00 0.85 1.190 242.00
17.00 0.90 1.350 273.00

32 x 7
(f=0.690 & k=0.830)

Rope diameter (mm) Outer Wire Diameter (mm) Mass (Kg/m) Minimum Breaking Load (kN)
18.00 0.95 1.535 312.00
19.00 1.00 1.710 348.00
20.00 1.07 1.930 389.00
21.00 1.13 2.130 430.00
22.00 1.17 2.315 468.00
23.00 1.23 2.530 510.00
24.00 1.27 2.750 551.40
25.00 1.33 2.990 598.00
26.00 1.37 3.210 642.00

35 x 7
(f=0.690 k=0.830)
Rope diameter (mm) Outer Wire Diameter (mm) Mass (Kg/m) Minimum Breaking Load (kN)
28.00 1.50 3.800 755.00
29.00 1.53 4.000 790.00
30.00 1.60 4.350 855.00
32.00 1.70 4.930 966.00
34.00 1.80 5.560 1090.00
36.00 1.90 6.240 1215.00
38.00 2.00 6.900 1357.00
40.00 2.10 7.600 1523.00
42.00 2.23 8.500 1661.00
44.00 2.33 9.300 1816.00
46.00 2.43 10.100 1962.00
48.00 2.53 11.000 2136.00

35 x 17
(f=0.689 & k=0.800)
the Outer wires are 1960 MPa
Rope diameter (mm) Outer Wire Diameter (mm) Mass (Kg/m) Minimum Breaking Load (kN)
52.00 2.23 13.100 2480.00
54.00 2.50 14.100 2675.00
58.00 2.50 16.300 3085.00
60.00 2.57 17.400 3302.00
64.00 2.75 19.800 3757.00
67.00 2.90 21.700 4118.00
71.00 3.05 24.400 4625.00

35 x 26 WS
(f=0.693 & k=0.800)
the Outer wires are 1960 MPa

Rope diameter (mm) Outer Wire Diameter (mm) Mass (Kg/m) Minimum Breaking Load (kN)
74.00 2.67 26.700 4975.00
77.00 2.77 28.900 5385.00
80.00 2.87 31.200 5815.00
83.00 3.00 33.600 6260.00

Safety: The geometrical composition of NOTOR HP is designed to protect the core. Any deterioration in the rope will first become evident in broken Outer wires, and thus can be used as a guide to discard. This feature has been extensively tested and proved in our laboratory and confirmed by customers. NOTOR HP gives excellent performance under the most severe conditions, its recommended for Tower cranes, Mobile cranes, High electrical hoists or any hoisting application requiring high performance together with a critical Breaking load.

Diameter tolerance -1 + 4%

COMPLAST Series: Plastic Impregnated NOTOR HP
The use of plastic gives internal protection and cushions the outer strands thus ensuring NOTOR HP COMPLAST has a perfectly homogeneous structure resulting in high performance.

NOTOR HP COMPLAST: for Deck cranes, Multi-fall revving systems, and Fleet angles.



NRHD 24

  • Equal layed steel core to prevent cross nicking
  • Langs lay
  • Galvanised steel 2160 MPa
  • Specific lubrication
24 x 7
(f=0.625 & k=0.815)
Rope diameter (mm) Outer Wire Diameter (mm) Mass (Kg/m) Minimum Breaking Load (kN)
7.20 0.45 0.210 42.00
8.00 0.52 0.270 56.00
9.00 0.57 0.335 68.50
10.00 0.63 0.420 86.00
11.00 0.70 0.510 104.00
12.00 0.77 0.605 124.50
13.00 0.83 0.710 145.00
14.00 0.90 0.855 175.00
15.00 0.95 0.940 190.00
16.00 1.03 1.180 220.00
18.00 1.15 1.360 275.00
19.00 1.23 1.535 310.00
20.00 1.27 1.670 335.00
22.00 1.40 2.030 410.00

24 x 17
(f=0.625 & k=0.815)
Rope diameter (mm) Outer Wire Diameter (mm) Mass (Kg/m) Minimum Breaking Load (kN)
Rope diameter (mm) Outer Wire Diameter (mm) Mass (Kg/m) Minimum Breaking Load (kN)
24.00 1.27 2.500 495.00
25.40 1.33 2.745 560.00
26.00 1.37 3.240 675.00

24 x 17 C
(f=0.625 k=0.815)
the Outer wires are 1960 MPa
Rope diameter (mm) Outer Wire Diameter (mm) Mass (Kg/m) Minimum Breaking Load (kN)
30.00 1.63 4.240 760.00
32.00 1.73 4.780 865.00
34.00 1.85 5.400 980.00
36.00 1.95 6.050 1090.00
38.00 2.07 6.770 1215.00
40.00 2.17 7.530 1345.00
42.00 2.27 8.230 1485.00
44.00 2.40 9.100 1630.00
46.00 2.50 9.950 1825.00
48.00 2.60 10.790 1980.00

24 x 21
(f=0.643 & k=0.780)
the Outer wires are 1960 MPa
Rope diameter (mm) Outer Wire Diameter (mm) Mass (Kg/m) Minimum Breaking Load (kN)
52.00 2.33 12.100 2270.00
54.00 2.43 13.100 2245.00
58.00 2.60 15.100 2810.00
60.00 2.70 16.200 2980.00

24 x 26
(f=0.646 & k=0.780)
the Outer wires are 1960 MPa
Rope diameter (mm) Outer Wire Diameter (mm) Mass (Kg/m) Minimum Breaking Load (kN)
64.00 2.87 18.500 3460.00
67.00 3.00 20.200 3770.00
71.00 3.20 22.800 4260.00
74.00 3.33 24.800 4600.00
77.00 3.45 26.700 4955.00
80.00 3.60 28.900 5270.00
82.00 3.67 30.300 5535.00

Safety: Core protection is maintained due to linear contact between the core wires and Outer strands preventing cross-nicking.  Any deterioration in the rope will first become evident in broken outer wires and can thus be used as a guide to discard.  This feature has been extensively tested and proved in our laboratory, and confirmed by customers.

NRHD 24 is recommended for any difficult hoisting application on Tower cranes, Mobile cranes or any installation requiring a high fatigue resistance, Multi-layering or a high degree of flexibility.

Diameter tolerance -1 + 4%

COMPLAST Series: NRHD 24 Plastic Impregnated
The use of plastic gives internal protection and cushions the outer strands thus ensuring NRHD 24 has a perfectly homogeneous structure resulting in high performance.



AGM NUFLEX

  • Ordinary lay
  • Galvanised steel 2160 MPa
  • Steel core
  • Specific greasing
  • Economical
  • Reliable
  • Durable

17 x 7
(f=0.600 & k=0.805)
Rope Diameter (mm) Outer Wire Diameter (mm) Mass (Kg/m) Minimum Breaking Load (kN)
6.00 0.40 0.145 29.10
6.70 0.45 0.185 37.00
7.00 0.47 0.200 40.40
7.50 0.50 0.225 44.90
8.20 0.55 0.275 54.80
8.50 0.57 0.290 58.40
9.00 0.60 0.322 64.90
10.00 0.67 0.405 82.00
10.50 0.70 0.450 88.40
11.00 0.75 0.510 101.00
12.00 0.80 0.580 114.80
13.00 0.87 0.690 142.00
14.00 0.95 0.825 165.00
14.50 1.00 0.905 182.00
16.00 1.10 1.110 223.00
18.00 1.20 1.315 264.00





Latch & Batchelor Ltd, Hay Mills, Birmingham, England, B25 8DW. T. 0121 772 9799. F. 0121 766 7692.